| Main parameters of linacs | |||||||
| in the RNB facility | |||||||
| SCRFQ/IH LINAC | RFQ | IH | |||||
| Frequency (f) | 25.96 | 51.92 | MHz | ||||
| Total length | 8.6 | 5.6 | m | ||||
| Diameter | 0.9 | 1.49 for tanks 1-3 | m | ||||
| 1.34 for tank 4 | m | ||||||
| Synchronous phase (f) | -30 | -25 | deg. | ||||
| Charge-to-mass ratio (q/A) | ³1/28 | ³1/10 | |||||
| Input energy (Tin) | 2.1 | 178 | keV/u | ||||
| Output energy (Tout) | 0.178 | 0.14-1.09 | MeV/u | ||||
| Normalized acceptance (An) | 0.86p | 1.7p | mm·mrad | ||||
| Duty factor | 30 | 100 | % | ||||
| Repetition rate | 20-1000 | Hz | |||||
| IH2 LINAC | Tank 1 | Tank 2 | |||||
| Frequency (f) | 129.8 | MHz | |||||
| Tank length | 1.15 | 1.35 | m | ||||
| Synchronous phase (f) | -25 | deg. | |||||
| Charge-to-mass ratio (q/A) | ³1/7 | ||||||
| Normalized acceptance | 1.4p | mm·mrad | |||||
| Input energy (Tin) | 1.05 | 1.54 | MeV/u | ||||
| Output energy (Tout) | 1.54 | 2.03 | MeV/u | ||||
| Gap voltage (Vg) | 250 | kV | |||||
| Duty factor | 100 | % | |||||
| SC-LINAC | |||||||
| Frequency (f) | 129.8 | MHz | |||||
| Number of cavities | 40 | ||||||
| Cavity | l/4 resonator | ||||||
| Gap voltage (Vg) | 0.375 | MV | |||||
| Optimum ion velocity (b0) | 0.1 | ||||||
| Synchronous phase (f) | -25 | deg. | |||||
| Input energy (Tin) | 2 | MeV/u | |||||
| Output energy (Tout) | 5 for q/A=1/7 | MeV/u | |||||
| 8 for q/A=1/4 | |||||||
| Normalized acceptance | 1.4p | mm·mrad | |||||
| Duty factor | 100 | % | |||||